Microscope.com - The Microscope Store LLC

Call Us Toll-Free: (877) 409-3556

Hours of Operation - Contact Us by Email

Microscopes for everyday use

Check Out
Shopping Cart
0 items  $0.00 
  Home » » Compound Microscope Parts  |  My Account  |  Checkout  
By Type
CLOSE OUT SPECIALS
Microscope Packages
Compound Microscopes
Stereo Microscopes
Microscope Accessories
Microscope Cameras
Boom Microscopes
Digital Microscopes
Dino-Lite
Video Inspection Systems
Magnifier / Magnifying Lamps
Inverted Microscopes
Portable Microscopes
Metallurgical Microscopes
Polarizing Microscopes
Phase Contrast Microscopes
Fluorescence Microscopes
Monocular Microscopes
Trinocular Microscopes
By Application
Asbestos I.D/Counting
Engraving
Gemology/Jewelry
Gift Suggestions
Industrial Inspection
Live Blood Analysis
Mineralogy/Metallurgy
Student Microscopes
Teaching
Microscope Cameras
Microscope Camera Adapters
   Information
About Us
Shipping & Returns
Hours of Operation
Privacy Notice
Our Customers
Customer Comments
Software Support
Product Manuals
Warranty Information
Microscope Blog
My Wishlist
Gift Voucher FAQ
Contact Us
   Resources
About Microscopes
Barlow Lens
Buying a Microscope
CAREERS
Compound Microscope History
Compound Microscope Parts
Dino-Lite Buyers Guide
Imaging Terms
Magnifier Buyers Guide
Microscope Maintenance
Microscope Terms
Microscope Troubleshooting
Omano Microscope Bulbs
Using a Compound Microscope
Product Specification Charts
Microscope Books
Compound Microscope Parts

A high power or compound microscope achieves higher levels of magnification than a stereo or low power microscope. It is used to view smaller specimens such as cell structures which cannot be seen at lower levels of magnification.

Essentially, a compound microscope consists of structural and optical components. However, within these two basic systems, there are some essential components that every microscopist should know and understand.

These key microscope parts are illustrated and explained below.

STRUCTURAL COMPONENTS

The three basic structural components of a compound microscope are the head, base and arm.

  • Head/Body houses the optical parts in the upper part of the microscope
  • Base of the microscope supports the microscope and houses the illuminator
  • Arm connects to the base and supports the microscope head. It is also used to carry the microscope.

When carrying a compound microscope always take care to lift it by both the arm and base, simultaneously.

Compound Microscope parts from Microscope.com

OPTICAL COMPONENTS

There are two optical systems in a compound microscope: Eyepiece Lenses and Objective Lenses:

Eyepiece or Ocular is what you look through at the top of the microscope. Typically, standard eyepieces have a magnifying power of 10x. Optional eyepieces of varying powers are available, typically from 5x-30x.

Eyepiece tube holds the eyepieces in place above the objective lens. Binocular microscope heads typically incorporate a diopter adjustment ring that allows for the possible inconsistencies of our eyesight in one or both eyes. The monocular (single eye usage) microscope does not need a diopter. Binocular microscopes also swivel (Interpupillary Adjustment) to allow for different distances between the eyes of different individuals.

Objective Lenses are the primary optical lenses on a microscope. They range from 4x-100x and typically, include, three, four or five on lens on most microscopes. Objectives can be forward or rear-facing.

Nosepiece houses the objectives. The objectives are exposed and are mounted on a rotating turret so that different objectives can be conveniently selected. Standard objectives include 4x, 10x, 40x and 100x although different power objectives are available.

Coarse and Fine Focus knobs are used to focus the microscope. Increasingly, they are coaxial knobs - that is to say they are built on the same axis with the fine focus knob on the outside. Coaxial focus knobs are more convenient since the viewer does not have to grope for a different knob.

Stage is where the specimen to be viewed is placed. A mechanical stage is used when working at higher magnifications where delicate movements of the specimen slide are required.

Stage Clips are used when there is no mechanical stage. The viewer is required to move the slide manually to view different sections of the specimen.

Aperture is the hole in the stage through which the base (transmitted) light reaches the stage.

Illuminator is the light source for a microscope, typically located in the base of the microscope. Most light microscopes use low voltage, halogen bulbs with continuous variable lighting control located within the base.

Condenser is used to collect and focus the light from the illuminator on to the specimen. It is located under the stage often in conjunction with an iris diaphragm.

Iris Diaphragm controls the amount of light reaching the specimen. It is located above the condenser and below the stage. Most high quality microscopes include an Abbe condenser with an iris diaphragm. Combined, they control both the focus and quantity of light applied to the specimen.

Condenser Focus Knob moves the condenser up or down to control the lighting focus on the specimen.

View our full range of compound microscopes including Omano and Meiji Techno compound microscopes.

 

 

   Specials more
Motic DMW-143 - Triple Output, Digital Stereo Microscope
Motic DMW-143 - Triple Output, Digital Stereo Microscope
$1,338.00
$1,319.00
   Reviews more
Omano OM136CL 400x Compound Monocular Scope
I am very happy because this is a great microscope. My fathe ..
5 of 5 Stars!
BBB Accredited Business seal
PriceGrabber User Ratings for Microscope.com
© Microscope.com
1222 McDowell Ave NE, Roanoke, VA 24012
Phone: (540) 904-0880     Toll Free: (877) 409-3556     Fax: (540) 904-0885